Layout settings

 

Section

Setting

Default

Description

Panel

Settings for:

 

Select the modality the settings on this page apply to. Select the modality type Default to set the default settings for all the undefined parameters.

Monitor setting

Multiple monitor

Enabled

Permit the viewer to appear on all enabled monitors for the selected modality type. This setting is effective only when multiple viewer monitors are configured enabled, or the number of monitors configured on the view page is greater than 1.

Automatic settings

Find localizers

Enabled

When enabled, separate localizer images grouped in series with non-localizer images into their own series. When disabled, localizer images are grouped as specified by the object data.

Split series

Disabled

Some series contain images in different planes, or using different acquisition parameters. The viewer can sometimes identify these series. When Split series is enabled, the images are grouped together into individual series and made available to the user. When disabled, the series are grouped as specified by the object data.

Sort series

Disabled

When enabled, always sort the images by image position, or slice number when position information is unavailable. When disabled, the series is ordered as it arrived at the server.

Series split length

0

For series with fewer images than specified in the Series split length setting, separate all images into their own series. Useful for separating CR series into single images. Maximum value is 12.

Thumbnail size

Use default size

Enabled

Use the default thumbnail size.

Size

 

Override the default thumbnail size for the selected modality. The value is defined in pixels-squared

 

Report figure size

Use default size

Enabled

Use the default image size.

Size

 

Override the default figure size for the selected modality. The value is defined in pixels-squared.

Report panel

Use default setting

Enabled

Use the default BIRAD setting

Show BIRADS

 

Display BIRADs list on the report panel for the selected modality

Navigation bar

Use default setting

Enabled

Use the default Navigation Bar setting.

Show

Auto

Display or hide the navigation toolbar. Options include On, Off and Auto (default). When set to auto, the navigation toolbar appears when the current view defines one or more pages or monitors.

Image Layout

Use default setting

Enabled

Use the default image layout setting.

Tile across monitors

 

When selected, the selected tile mode is applied across all enabled monitors.

N-up

 

The default grid layout for the selected modality type.

Custom

 

Define a custom grid layout for the selected modality type.

Template

Use default template

Enabled

Use the default hanging protocol template setting.

Template menu

 

Select the hanging protocol template to apply to studies of the selected modality type.

Show layout manager

Enabled

When enabled, display the layout manager after applying a hanging protocol template. When disabled and a template was automatically applied, do not show the layout manager.

General

Auto-load localizers

Enabled

When enabled, include localizer images when automatically loading series into image frames.

Use hanging protocol assistant

Enabled

When enabled, the hanging protocol assistance attempts to select the best-defined hanging protocol template based on previous usage. When disabled, the Template settings take precedence.

 

Reset hanging protocol rules

 

Reset the learned hanging protocol rules to the default values.