Setting |
Description |
Settings for: |
Select the modality the settings on this page apply to. Select the modality type Default to set the default settings for all the undefined parameters. |
Use the default list for this display location |
Instructs the viewer to use either the default setting for the specified Display Location, or to customize the Display Location for the selected modality type. When checked, the default settings are used. When cleared, the control panel is activated and you can customize the attributes. The default is checked. |
[Control panel] |
Work area for organizing the selected attributes to display in the area specified in Display Location. Clear the check in the Use the default list… box to activate this area. |
Display Location: |
The areas of the image, panel and film displaying demographic and study information. The available options include the following Top-left/Anterior – Top, left or top, anterior corner of an image or print frame Top-right/Posterior – Top, right or top posterior corner of an image or print frame Bottom-left/Anterior – Bottom, left or bottom, anterior corner of an image or print frame Bottom-right/Posterior – Bottom, right or bottom, posterior corner of an image or print frame Thumbnail study header – The study header(s) in the Thumbnail panel Thumbnail series header – The header above each series in the Thumbnail panel Thumbnail series footer – The footer below each series in the Thumbnail panel Thumbnail top – Overlaid on the top of the series image in the Thumbnail panel Thumbnail bottom – Overlaid on the bottom of the series image in the Thumbnail panel Print Header – Submitted to the printer as the page header |
Character Size: |
The font size of the overlay data. The font type is not configurable. |
Precision |
Rounds the integer and decimal portions of a numeric field value to the specified number of characters. |
Tag: |
List of available attributes tags from the DICOM object. This list is created from the attributes defined in the object loaded in the viewer. If the attribute does not exist in this list, it is not defined in the DICOM object. |
Info: |
List of calculated values that can be used in overlays. |
Move Up/Down |
Move the selected item in the control panel up or down the list. |
Remove |
Click this button to remove the item selected in the control panel. |
Add Tag |
Click this button to add an attribute from the Tag list. |
Add Info |
Click this button to add a value from the Info list. |
Add Text |
Click this button to add a text string. |
Break |
Click this button to insert a carriage return (new-line) character. |
Font Type |
Override the default font type with the selected value |
Font Size |
Override the default font size with the selected value |
Font Color |
Override the default font color with the selected value |
Transparency |
Define the label transparency value |
Bold |
Make the label font bold |
Italic |
Make the label font italicized |
The Info list contains calculated values, generated by the viewer and based on the loaded study. The list of available values in the Info list is as follows:
Info Field |
Description |
Augmentation |
Processed keyword value used by hanging protocol assistant to identify the series description. |
Completion |
The percentage of the image that has already downloaded to the viewer. |
Compression |
The compression ratio applied to the image. |
Current Annotation |
If an annotation is currently selected, the value of that annotation (i.e., the length, area, text string, etc.) appears in the overlay. |
HP Series Info |
Hanging protocol’s matching criteria information. |
Image Index |
The position of the image in the series. This is different from the Instance Number in the Tag list. The Instance Number is a value defined by the modality, and is not guaranteed to be sequential. The Image Index uses the position in the series, and therefore is always sequential. |
Level |
Current window center setting. |
Packet Size |
Size of the network packets in the download transmission. |
Primary Status
|
Displays one of the following values: Current – the image is an object in the primary study. Prior <N> – the image is an object in a related prior (to the primary study). The number, N, represents one less than the ordinal value of the study in the thumbnail panel. Unrelated – the image is unrelated to the primary study. |
Renderer |
Image rendering method: sw (software), bd (hardware) or d3d (Direct3D). |
Series Size |
Total number of images in the series. |
Window |
Current window width setting. |
Zoom |
The zoom factor currently applied to the image. |
To access data within a DICOM sequence, use viewer coercion to extract the information into a user or custom field, and then apply that field to the DICOM Field configuration.
The Thumbnail panel header information can be customized by editing the Thumbnail study header, series headers and overlay data. Select the respective field from the Display Location list and add tag, info and text fields as needed. The series header, footer, top overlay and bottom overlay fields are limited to a single line. The value is truncated if too long. Truncated series header and footer values are displayed by positioning the mouse over the field. If the series header or footer location is empty, the field is hidden in the Thumbnail panel.
For studies with a Modality value of MG, the display location refers to the anterior and posterior sides of the image. On these images, the overlay information is relative to the image and not the image frame. If the viewer cannot detect the anterior and posterior edge of the mammography image, the associated left or right location shall apply.
The font characteristics of the data displayed as image overlay, thumbnail study header and series headers and footers, and the thumbnail top/bottom locations can customized individually. The default colors are defined in the Customize Settings Color panel. The default font size is defined in the Character Size field in this panel. Field-specific settings override these. To customize a specific field, do the following:
You can embed multiple font settings within existing control entries.
To remove a font control setting, you must remove both the preceding and trailing control entries, as follows: